Rapid and Precise Carbon Dioxide Clumped Isotope Composition Analysis by Tunable Infrared Laser Differential Absorption Spectroscopy

David Nelson1, Zhennan Wang2, David Dettman2, Barry McManus1, Jay Quade2, Nitzan Yanay2, Katharine Huntington3, and Andrew Schauer3
David Nelson et al.
  • 1Aerodyne Research, Inc., Billerica, United States of America (ddn@aerodyne.com)
  • 2Dept. of Geosciences, University of Arizona, Tucson, United States of America
  • 3College of the Environment in Earth Systems, University of Washington, Seattle, United States of America

Carbon dioxide clumped isotope thermometry is one of the most developed applications of the geochemistry of multiply substituted isotopologues. The degree of heavy isotope clumping (e.g., 16O13C18O) beyond an expected random distribution can be related to the temperature of calcite precipitation. This provides an independent temperature estimate that, when combined with carbonate δ18O values, can constrain paleowater δ18O values. However, the use of isotope ratio mass spectrometry (IRMS) to do these measurements remains relatively rare because it is time-consuming and costly. We have developed an isotope ratio laser spectrometry method using tunable infrared laser differential absorption spectroscopy (TILDAS) and describe our latest results using both gaseous carbon dioxide samples and CO2 derived from carbonate minerals. The TILDAS instrument has two continuous wave lasers to directly and simultaneously measure four isotopologues involved in the 16O13C18O equilibrium calculation. Because each isotopologue is independently resolved, this approach does not have to correct for isobaric peaks. The gas samples are trapped in a low volume (~250 ml) optical multi-pass cell with a path length of 36 meters. Raw data are collected at 1.6 kHz, providing 96,000 peak-area measurements of each CO2 isotopologue per minute. With a specially designed sampling system, each sample measurement is bracketed with measurements of a working reference gas, and a precision of 0.01‰ is achieved within 20 minutes, based on four repeated measurements. The total sample size needed for a complete measurement is approximately 15 μmol of CO2, or 1.5 mg of calcite equivalent. TILDAS reported ∆16O13C18O values show a linear relationship with theoretical calculations, with a very weak dependence on bulk isotope composition. The performance of the TILDAS system demonstrated in this study is competitive with the best IRMS systems and surpasses typical IRMS measurements in several key respects, such as measurement duration and isobaric interference problems. This method can easily be applied more widely in stable isotope geochemistry by changing spectral regions and laser configurations, leading to rapid and high precision (0.01‰) measurement of conventional stable isotope ratios and δ17O in CO2 gas samples.

How to cite: Nelson, D., Wang, Z., Dettman, D., McManus, B., Quade, J., Yanay, N., Huntington, K., and Schauer, A.: Rapid and Precise Carbon Dioxide Clumped Isotope Composition Analysis by Tunable Infrared Laser Differential Absorption Spectroscopy, EGU General Assembly 2020, Online, 4–8 May 2020, EGU2020-11501, https://doi.org/10.5194/egusphere-egu2020-11501, 2020

This abstract will not be presented.